ProposalWorkspaceFederal OpportunitiesDepartment of Veterans Affairs

6515--Fresenius 5008X Machines

Active 36C24827Q0152 Sources SoughtDepartment of Veterans Affairs
The full text, documents and contacts of this bid come with a ProposalWorkspace plan.Get started

At a glance

248-Network Contract Office 8 (36C248) of Department of Veterans Affairs posted this Sources Sought on Nov 19, 2026. Responses are due Nov 30, 2026. NAICS 334510 (Electromedical and Electrotherapeutic Apparatus Manufacturing), product or service code 6515 (Medical and Surgical Instruments, Equipment, and Supplies). Place of performance: Puerto Rico 00921. Solicitation number 36C24827Q0152.

Solicitation details

General information

Solicitation number
36C24827Q0152
Notice type
Sources Sought
Place of performance
Puerto Rico 00921

Classification

NAICS
334510Electromedical and Electrotherapeutic Apparatus Manufacturing
Product or service
6515Medical and Surgical Instruments, Equipment, and Supplies

Agency

Department
Department of Veterans Affairs
Sub-tier
Department of Veterans Affairs
Office
248-Network Contract Office 8 (36C248)

Description

From SAM.gov
This is a Sources Sought Notice only. It is neither a solicitation nor a request for a quote, and it does not obligate the Government to award a contract. Quotes received in response to this notice will not receive a response. The Government will not pay or reimburse any costs of preparing this response. The purpose of this notice is for market research purposes only and to make appropriate acquisition decisions to gain knowledge of potential qualified businesses and their Small Business Administration (SBA) size classification in relation to North American Industry Classification System (NAICS) 334510, Electromedical and Electrotherapeutic Apparatus Manufacturing with a size standard of 1,250 employees. The Network Contracting Office (NCO) 8, VA Caribbean Healthcare System, located in San Juan, Puerto Rico, is seeking a business that can provide an EQUAL to the Fresenius 5008X CAREsystem. NOTE: The following list includes items manufactured by Fresenius Medical Care. We are requesting information about an EQUAL product with the preference at this time for domestic products. The domestic product must meet or exceed the salient characteristics provided as follows: BRANDNAME Product Number Description M204441 5008X CARESystem + CLiC + CDX F50044946 Support plate F50044953 Acid connector guide 1 Gal F50035686 Kit Insulated Water Inlet Tube 5008X CAREkit-7 FX100 CORAL F00012971 + CliC 03-5300-3C CAREkit-8 FX120 CORAL F00012972 + CLiC 03-5300-3C 08-4080-BB bibag 900 grams/bag 12 bags/case 04-3000-9 5008X HD/HDF Medication Line 04-9009-4 Fluid Sampling Accessory 5008X 28-0600-1 CitraSure Disinfectant Including Clinical Training Including 2 Biomed tokens for training EQUAL Must deliver FDA cleared high volume online hemodiafiltration (HVHDF), no exception. Must be able to achieve convection volumes meeting or exceeding 23 L per session via hemodiafiltration therapy. Must have automatic fluid substitution control to allow achieving safely convection volumes of 23 L per session. Must provide option for real time fluid status monitoring to minimize intradialytic hypotension. Must generate sterile, non pyrogenic substitution fluid on demand and comply with dialysis water standards. Must be compatible with high flux dialyzers to enhance uremic toxin clearance. Must demonstrate FDA clearance for the specific device, Hemodialysis and High Volume Hemodiafiltration therapy modes. Must have technical support available to Puerto Rico, through the expected 10-year lifecycle. Must have availability of replacement parts and consumables deliverable to Puerto Rico. Must comply with IEC 60601 medical electrical safety standards and Class II device requirements. Must be domestic-origin product. Concerns may respond by submitting a qualifications letter including the following information: Company Name, Address, Point of Contact, Phone Number, FAX, Email, System for Award Management (SAM) Unique Identifier Code (UEI), Socio-Economic Category i.e.,(SDVOSB, VOSB, HUBZone, etc.) and Capability Statement specific to the technical requirements, authorized distributor letter, and include a product brochure, if possible. Provide evidence that your firm can provide the requested items, including past and/or current contracts for the same requirements, and any other compelling evidence to help the Government determine your company's capabilities. To be eligible for an award, prospective offerors must be registered on the SAM website, https://sam.gov/content/home. Responses to this notice shall be sent via email no later than 5:00 PM EST on November 30, 2026. Telephone and facsimile responses will not be considered. Please email Contract Specialist Eunice Bones at eunice.bones@va.gov. When responding via email, ensure the subject line is titled with RFI# 36C24827Q0152-Fresenius 5008X Machines. No further information is available at this time. We thank you for your time and interest.

Documents

1 file

Subscribe to download this file.

  • RFI 36C24827Q0152.pdf
    129 KB · Nov 19, 2026
    Download

Similar open bids

Same NAICS 334510

More from Department of Veterans Affairs

Open bids, other NAICS codes