ProposalWorkspaceFederal OpportunitiesDepartment of Veterans Affairs

J012--Fire Suppression System Maintenance and

Active 36C25027Q0078 SolicitationDepartment of Veterans Affairs
The full text, documents and contacts of this bid come with a ProposalWorkspace plan.Get started

At a glance

250-Network Contract Office 10 (36C250) of Department of Veterans Affairs posted this Solicitation on Nov 24, 2026. Responses are due Dec 8, 2026. NAICS 811310 (Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance), product or service code J012 (Maint/Repair/Rebuild of Equipment - Fire Control Equipment). Solicitation number 36C25027Q0078.

Solicitation details

General information

Solicitation number
36C25027Q0078
Notice type
Solicitation

Classification

NAICS
811310Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
Product or service
J012Maint/Repair/Rebuild of Equipment - Fire Control Equipment

Agency

Department
Department of Veterans Affairs
Sub-tier
Department of Veterans Affairs
Office
250-Network Contract Office 10 (36C250)

Description

From SAM.gov
1. Monthly Fire Suppression Inspections PWS Sections 5, 6.1, and Appendix B The revised PWS shows Section 6.1 (Monthly Inspections) and the corresponding monthly inspection requirement in Appendix B as struck through. However, Sections 1 and 5 and Appendix A still reference monthly inspections. Could the Government please confirm whether the requirement for monthly inspections of all 10 fire suppression systems (120 inspections annually) has been officially removed, leaving only the semiannual maintenance and certification requirements? Leaving these references in was an error. All references to monthly inspections should be disregarded, as they are no longer required. 2. Monthly Reconciliation and Deficiency Log PWS Section 10 and Appendix B The revised Appendix B shows the monthly reconciliation and deficiency log deliverable as struck through, while Section 10 continues to require monthly reconciliation by the fifth business day of the following month. Could the Government confirm whether monthly reconciliation reports are still required, or whether this reporting obligation has been removed? We understand that service-specific deficiency reporting remains applicable. Section 10 is not referencing monthly inspections. It is references service reports. Since work is not being done monthly, the language should be revised to say,   With each service report, the Contractor shall update the cumulative equipment inventory, service log, and deficiency log. Identify required services that were not completed, the reasons, and proposed completion dates. Update open deficiencies when corrective work is completed. A combined visit may satisfy multiple required activities only when each activity and its results are separately documented. A separate monthly reconciliation report is not required. 3. Existing Deficiencies and Six-Year Cylinder Maintenance PWS Section 9 The historical kitchen exhaust cleaning reports identify inaccessible duct sections, recommended access-panel installations, and other conditions requiring corrective action. Additionally, the October 2026 fire suppression inspection records identify six-year maintenance concerns affecting the Kidde dry-chemical systems, while the November 2026 maintenance documentation appears to address four cylinders. Could the Government please clarify: Whether the identified duct-access deficiencies will be corrected before the new contract begins or addressed separately through Contracting Officer-authorized corrective work. Whether the six-year maintenance requirements have been fully completed for all five Kidde IND-21 systems, or whether any outstanding work remains. Whether any unresolved pre-existing deficiencies should be excluded from recurring fixed-price services and handled through separate authorization under Section 9. The Six-Year maintenance deficiency was corrected on November 19th, 2026. The VA is not aware of any duct-access deficiencies, this was not listed in the previous report to the one you referenced and may be an administrative error. Offeror should make their own assessment during a scheduled site visit.

Documents

14 files

Subscribe to download these 14 files.

  • ATTACHMENT III - RFI Form.docx
    17 KB · Nov 6, 2026
    Download
  • ATTACHMENT II - VAAR 852.219-75.docx
    17 KB · Nov 6, 2026
    Download
  • ATTACHMENT I - SCA WD.pdf
    69 KB · Nov 6, 2026
    Download
  • 36C25027Q0078.pdf
    580 KB · Nov 6, 2026
    Download
  • 36C25027Q0078 0001.docx
    878 KB · Nov 19, 2026
    Download
  • 6 Year Tank maintenance.pdf
    6.1 MB · Nov 19, 2026
    Download
  • Kitchen Hood and Exhaust Cleaning Report April 2026.pdf
    2.8 MB · Nov 19, 2026
    Download
  • Kitchen Hood and Exhaust Cleaning Report October 2026.pdf
    94 KB · Nov 19, 2026
    Download
  • Monthly Inspection October 2026.pdf
    8.6 MB · Nov 19, 2026
    Download
  • PWS Hood Inspection and Cleaning updated.pdf
    153 KB · Nov 19, 2026
    Download
  • Semi-Annual Fire Suppression System Inspection December 2025.pdf
    171 KB · Nov 19, 2026
    Download
  • Semi-Annual Fire Suppression System Inspection June 2026.pdf
    2.9 MB · Nov 19, 2026
    Download
  • Semi-Annual Fire Suppression System Inspection October 2026.pdf
    215 KB · Nov 19, 2026
    Download
  • 36C25027Q0078 0002.docx
    29 KB · Nov 24, 2026
    Download

Similar open bids

Same NAICS 811310

More from Department of Veterans Affairs

Open bids, other NAICS codes