ProposalWorkspaceFederal OpportunitiesDepartment of Veterans Affairs

Z2DA--657-27-111JB, Install Continuous Water Monitoring System,

Active 36C25527R0019 PresolicitationService-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)Department of Veterans Affairs
The full text, documents and contacts of this bid come with a ProposalWorkspace plan.Get started

At a glance

255-Network Contract Office 15 (36C255) of Department of Veterans Affairs posted this Presolicitation on Nov 23, 2026. Responses are due Dec 7, 2026. NAICS 238220 (Plumbing, Heating, and Air-Conditioning Contractors), product or service code Z2DA (Repair or Alteration of Hospitals and Infirmaries). Set-aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14). Place of performance: MO 63125. Solicitation number 36C25527R0019.

Solicitation details

General information

Solicitation number
36C25527R0019
Notice type
Presolicitation
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Place of performance
MO 63125

Classification

NAICS
238220Plumbing, Heating, and Air-Conditioning Contractors
Product or service
Z2DARepair or Alteration of Hospitals and Infirmaries

Agency

Department
Department of Veterans Affairs
Sub-tier
Department of Veterans Affairs
Office
255-Network Contract Office 15 (36C255)

Description

From SAM.gov
Project # 657-27-111JB, Install Continuous Water Monitoring System The Department of Veterans Affairs, Network Contracting Office (NCO) 15, has a requirement for Installing a Continuous Water Monitoring System, project number 657-27-111JB, located at the U.S Department of Veterans Affairs, Str. Louis VAMC Jefferson Barracks 1 Jefferson Barracks Drive St. Louis, MO 63125 The following narrative is intended to provide an overview of the scope of work for the proposed project. Period of Performance 210 calendar days after Notice to Proceed (NTP) Scope of Work Contractor shall completely prepare site for building operations, including demolition and removal of existing structures, and furnish labor and materials and perform work for project 657-27-111JB. Justification: This project is required to be in compliance with VHA Directive 1061 to provide Legionella Prevention measuring devices. Building 3: 1 incoming cold water continuous monitoring with pressure and temperature 1 cold water distal Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Building 51: 1 incoming cold water continuous monitoring with pressure and temperature 2 cold water distal -Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Building 52: 1 incoming cold water continuous monitoring with pressure and temperature 1 cold water distal Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Building 53: 1 incoming cold water continuous monitoring with pressure and temperature 1 cold water distal Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Building 59: 1 incoming cold water continuous monitoring with pressure and temperature 1 cold water distal Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Provide full training of new water monitoring equipment and basic I&C training relating to this project. Contractor work must fully comply with VHA Directive 1061 The estimated project cost range to complete this work is Between $500,000 and $1,000,000. Pursuant to 38 USC 8127(d) and in accordance with Public Law 109-461, the Veterans Benefits, Health Care and Information Technology Act of 2006, this construction project will be solicited as a Total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The North American Industry Classification Code (NAICS) for this procurement is 238220 Plumbing, Heating and Air-Conditioning Contractors, with a small business size standard of $19.0 million. Contract Type: Firm Fixed. The duration of the project is estimated to be 210 calendar days from Notice to Proceed. This completion period includes final inspection and cleanup of the premises. Award will be made utilizing Highest technically rated with a fair and reasonable price approach in accordance with Federal Acquisition Regulation Part 15. Proposal submission instructions will be included in the solicitation package. The government plans to award without discussions. The offeror is responsible to monitor and download any amendments from the Contract Opportunities (https:// sam.gov) website, which may be issued to this solicitation. In accordance with FAR 52.204-7, Required SAM, and in accordance with Veterans Affairs Acquisition Regulation (VAAR) 802.101, prospective contractors must be registered in SAM and in the Veteran Small Business Certification (sba.gov) databases under the applicable NAICS. Firms may obtain SAM information at http://www.sam.gov and Veteran Small Business Certification (sba.gov) information at https://veterans.certify.sba.gov The solicitation package with project specifications and drawings should be available for download on or about December 7, 2026 and the proposal due date will be on or about January 15, 2027. An organized site visit will be scheduled and specific date and time will be made available at time of solicitation issuance. Only one site visit will be scheduled and interested offerors are highly encouraged to attend. No hard copies of the solicitation or drawings will be provided; and telephone requests or questions will NOT be accepted. Please email requests or questions to Jennifer.Hill@va.gov and ensure that the subject line reads "Install Continuous Water Monitoring System, Project Number 657-27-111JB; Solicitation Number: 36C25527R0019.

Documents

1 file

Subscribe to download this file.

  • 36C25527R0019_1.docx
    16 KB · Nov 23, 2026
    Download

Similar open bids

Same NAICS 238220

More from Department of Veterans Affairs

Open bids, other NAICS codes