ProposalWorkspaceFederal OpportunitiesDepartment of Defense

Electric Power Resiliency Building 56

Active SP330027Q0012 Combined Synopsis/SolicitationTotal Small Business Set-Aside (FAR 19.5)Defense Logistics Agency
The full text, documents and contacts of this bid come with a ProposalWorkspace plan.Get started

At a glance

DLA Distribution of Defense Logistics Agency posted this Combined Synopsis/Solicitation on Nov 13, 2026. Responses are due Dec 9, 2026. NAICS 238210 (Electrical Contractors and Other Wiring Installation Contractors), product or service code Z2GZ (Repair or Alteration of Other Warehouse Buildings). Set-aside: Total Small Business Set-Aside (FAR 19.5). Place of performance: 95304. Solicitation number SP330027Q0012.

Solicitation details

General information

Solicitation number
SP330027Q0012
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Place of performance
95304

Classification

NAICS
238210Electrical Contractors and Other Wiring Installation Contractors
Product or service
Z2GZRepair or Alteration of Other Warehouse Buildings

Agency

Department
Department of Defense
Sub-tier
Defense Logistics Agency
Office
DLA Distribution

Description

From SAM.gov
Amendment 0002 is being issued to correct faulty upload of Attachment 2.Amendment 0001 is being issued to add Attachment 2, which is the Statement of Work. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12 to accomplish at the Defense Distribution San Joaquin California. Contractor is to provide all labor, supervision, materials, tools, and equipment to design and modify the existing electrical system to include 500 KW AC roof mounted solar photovoltaic system for building 56. but not limited to: The solar photovoltaic (PV) system hardware and services shall meet or exceed all local, State and utility requirements, conform to the applicable codes and standards, and have passed the listing and qualification tests. All design and installation shall comply with the most recent version of each document. The final design of the on-site PV systems shall be the responsibility of the Contractor based on site conditions, roofing materials, and final system component selections by the Contractor. The systems must be compliant with applicable design guidelines. This Section identifies the minimum technical and installation specifications required. The PV systems shall be consistent with and adhere to all California Building Codes and standards, the California Solar Initiative program, and any and all CEC technical and installation specifications and guidelines. There is one existing electric substation feeding building 56 with a capacity: 12470/408V, 3000KVA transformer. Switchgear is rated: 4000A bus bar and four existing 1200A frame size circuit breaker spaces are available.

Documents

2 files

Subscribe to download these 2 files.

  • Attachment_2_SOW_SolarPV_Bldg_56.pdf
    413 KB · Nov 12, 2026
    Download
  • SP330027Q00120002.pdf
    212 KB · Nov 13, 2026
    Download

Similar open bids

Same NAICS 238210

More from Defense Logistics Agency

Open bids, other NAICS codes