Summary fields on this page were extracted by AI from the bid documents. Always verify dates, amounts and requirements against the official solicitation.
What the bid is for
The City of Hialeah is seeking quotes from qualified, licensed contractors to furnish all labor, materials, equipment, and supervision necessary for the removal of existing units and the fabrication and turn-key installation of commercial aluminum storefront entrance glass doors and fixed glass panel windows at Goodlet Theater (located within a partially enclosed atrium requiring exterior hurricane impact specifications).
All work must strictly adhere to the current Florida Building Code (FBC), High-Velocity Hurricane Zone (HVHZ) provisions, and the applicable Florida Product Approval or Miami-Dade County Notice of Acceptance (NOA) guidelines.
Scope
Product Specifications
All supplied door and window units must meet the following universal material and performance specifications, as detailed in the attached project schematic:
- System Basis of Design: Heavy-Duty Commercial Aluminum Storefront System, Large Missile Impact (LMI) rated.
- Frame Finish: Factory White finish.
- Glazing Composition: Laminated, heat-strengthened (HS) impact-resistant glass consisting of 1/4" GRAY HS + 0.090 PVB + 1/4" CLEAR HS (U-Factor: 1.05, SHGC: 0.47).
- Design Pressure (DP): Minimum +80.0 / -80.0 PSF.
- Structural Reinforcement: JAMB 1 / MULL 1 structural reinforcement per manufacturer product approval specifications for installation into concrete block/masonry substrates.
- Item 1: Storefront Double Door with Sidelites Assembly (Ref: Mark 2). Quantity: One (1) complete assembly. Overall Rough Opening Dimensions: 148.0" Width x 85.0" Height.
- Item 2: Fixed 3-Panel Glass Window Assembly (Ref: Mark 3). Quantity: Two (2) complete assemblies. Overall Rough Opening Dimensions: 148.0" Width x 74.0" Height (each assembly).
Installation, Finishing, and Site Requirements
The Contractor shall perform a complete, turn-key installation including the following services:
- Submittals: Prior to fabrication or ordering, the Contractor must submit manufacturer cut-sheets, shop drawings, wind-load calculations (if required for permitting), hardware schedules, and active Florida Product Approval / Miami-Dade NOA documentation to the City Project Manager for review and approval.
- Extraction & Disposal of Existing Units: Safe removal, extraction, and lawful off-site disposal of the existing door assembly and two (2) window assemblies currently installed in the three (3) openings, followed by cleaning and preparation of the existing concrete block/masonry rough openings. (Note: No wall or partition demolition is required).
- Substrate Inspection & Structural Anchoring: [...] The Contractor shall furnish and install all required aluminum framing, mullions, jamb reinforcements, shims, and masonry-rated fasteners in strict accordance with the product's NOA / Florida Product Approval fastening schedule.
- Weatherproofing & Perimeter Finishing: Apply commercial-grade, NOA-approved interior and exterior perimeter sealants. [...]
- Hardware Calibration & Daily Cleanup: Calibrate and test all door swings, three-point latches, closers, and weather seals for smooth, code-compliant operation. [...]
- Permitting & Inspections: The Contractor is responsible for securing all required City of Hialeah Building Department permits and coordinating all required inspections.
- Warranties: Provide all standard manufacturer product warranties alongside a minimum one (1) year Contractor workmanship and installation warranty commencing upon final City acceptance.
Additional information
Each Response must be submitted electronically to the City's e-procurement Portal located at https://procurement.opengov.com/portal/cityofhialeahfl no later than the date and time specified below. Response received after said date and time or in any other format will not be considered and no time extensions will be granted.
Response requirements
- Upload the Quote on Your Company's Letterhead (response required).
- Required Certification(s)/License(s) (response required).
- Upload a copy of your Company's COI (response required).
- RESPONSE & PRICE PROPOSAL CONFIRMATION (response required): the Respondent explicitly agrees to honor all pricing and terms for a period of **sixty (60) calendar days** from the date of the Solicitation opening.
Insurance
- Workers' Compensation - Coverage A Statutory Limits (State of Florida or Federal Act).
- Commercial General Liability: Per Occurrence Limit - **$1,000,000**; General aggregate - **$2,000,000**.
- Business Automobile Liability: Combined Single Limit (Each Accident) - **$1,000,000**.
- Subcontractor Provider Insurance: $1,000,000 General Liability; Statutory Limits for workers compensation; $1,000,000 Automobile Liability.
The Contractor shall name the City as an Additional Insured on a primary and non-contributory basis.
Site visit
The Contractor is solely responsible for conducting a pre-installation site visit and independently verifying all final rough-opening measurements and field conditions prior to fabricating or ordering materials.
The City may award a contract to a Bidder only through action taken by the City Council.