Appendix D, Rider F, Item 3 now reads as:
Service Level: The University will develop service level agreements (SLA) with Contractors to ensure satisfactory performance of Carrier Ethernet circuits. [...] The University is seeking a dark fiber lease priced as a monthly recurring charge, with any one-time non-recurring charges listed separately (Appendix C, Tables 2 and 5).
Service Level
The University will develop service level agreements (SLA) with Contractors to ensure satisfactory performance of Carrier Ethernet circuits. These SLAs will outline standards for reliability and availability as well as remedies should performance fail to meet acceptable standards.
Carrier Ethernet
Tags 2 and 3: point-to-point E-Line services from each site to the Orono PoP (tag 2) and the Portland PoP (tag 3), delivered at the PoP tagged with the Site ID.
Tags 10 and 11: multipoint E-LAN services connecting all sites in a district with the Orono PoP (tag 10) and the Portland PoP (tag 11), delivered at the PoP tagged with the District Bridge ID.
The minimum bandwidth for any school or library is 1 Gbps. Each EVC must carry a 1500-byte MTU. No CoS or QoS profile is required. The University expects a committed information rate equal to the contracted bandwidth at each site.
Dark Fiber
Standard single-mode fiber meeting ITU-T G.652 (G.652.D preferred) or a compatible standard such as G.657.A, with SC/UPC connectors at both demarcation points. The University is not seeking an IRU. The Contractor retains ownership of the fiber and remains responsible for its maintenance and repair.
Measured end-to-end loss must not exceed 0.5 dB per kilometer, inclusive of all splices, plus 0.5 dB for each connector termination in the path.
All proposals will be scored under the evaluation criteria in Section 2.1.
Subcontracted services must be disclosed in the response (Section 1.1.3), and each subcontractor must be listed with the information requested in Appendix G, Question 2, and Appendix K, Question 2. The Contractor may not subcontract any part of the Contract without the University's prior written consent (Appendix D, Section 12).
The SPIN and FCC Registration Number requirements in Appendix I apply to the Respondent. The Respondent's signature on *Appendix B* certifies debarment status for the subcontractors named in its proposal.
Site surveys are the Respondent's responsibility and cost. Surveys before award are not required. Letters of agency are not available.
Use of AI tools is not prohibited, but it must be disclosed. To pass, a Respondent must also answer all Appendix K questions and agree to the Security and Use of AI terms in Appendix D (Section 2.1, Information Technology Security).
Subscribe to get this document.
The operating system for your proposal team - for federal and state contractors. Submit a polished proposal with minimal effort.
Plans from $129 a month, or $99 a month billed yearly.