Westshore Campus Massage Therapy (Bid Set)

Active TRIC-9AEBF3DC IFBConstruction - BuildingCuyahoga Community College
The full text, documents and contacts of this bid come with a ProposalWorkspace plan.Get started

At a glance

Cuyahoga Community College (Ohio) posted this IFB on Nov 16, 2026. Responses are due Dec 7, 2026. Category: Construction - Building. Solicitation number TRIC-9AEBF3DC.

Solicitation details

General information

Solicitation number
TRIC-9AEBF3DC
Notice type
IFB
Place of performance
Ohio

Agency and category

Agency
Cuyahoga Community College
Category
005Construction - Building
Source listing
Link with a plan

About this listing

ProposalWorkspace summary

This bid was found on the agency's procurement portal. The portal's own text is not republished here; the summary below was written by ProposalWorkspace's AI from the bid documents. The full posting is on the portal - subscribe to get the link.

Summary

AI-read from the bid documents

Summary fields on this page were extracted by AI from the bid documents. Always verify dates, amounts and requirements against the official solicitation.

What the bid is for

This project includes the renovation of Room 325/327 on the third floor of the Health Careers and Sciences Building on Cuyahoga Community College's Westshore Campus. The 1,227 SQFT room will be converted from a workout room to a massage therapy lab to be used for student learning and public clinic settings. Work includes the addition of interior casework, ceiling mounted privacy curtains, enclosing an alcove for soiled linen holdings, in floor power, and (2) two hand sinks.

Scope

The approved scope of the project is:

  • General Building Trade
  • Mechanical
  • Electrical
  • Plumbing

This project includes a 1,227 SQFT renovation (on the third level) of an existing 150,000 SQFT facility. Renovation work does not increase the building area or increase the number of occupants. The existing plumbing fixture count shall serve the building.

Contractor to install owner provided appliances and furnishings as shown on drawings. Coordinate connection of all required utilities and services.

The general contractor shall be responsible to contract with a licensed and bonded fire alarm consultant to design and install a code compliant fire alarm system in accordance with NFPA and shown herein. The fire alarm system shall be permitted under a separate permit.

All existing exterior wall systems + glazing to remain. All existing fire ratings are to be maintained.

Additional information

**Mandatory** site visit: Contractor shall visit the construction site to become familiar with the scope of work + determine the full extent and nature of partitions, finishes, fixtures, etc. to be removed.

The general contractor shall comply with all building code requirements of the local governing authority, and shall obtain and pay for all required permits, fees, inspections, with the exception of fees required for the plumbing, HVAC, and electrical portions of the work, which are the responsibility of the respective subcontractors. Owner/Tenant will pay for the building permit.

This is a **phased construction approval** per 105.1.4 OBC. *Partial Plan Approval #3* does not include sprinkler shop drawings or plumbing. An approved set of plans be kept at the site and shall be available for reference by the building official at all times during working hours while such work is in progress.

Inspections must be scheduled on the Division of Industrial Compliance customer portal. If the number of inspections requested exceeds the maximum allowable number for each scope of work, an additional inspection fee of **$150.00** will be charged for each inspection.

This plan approval will expire if the work is delayed or suspended for more than (6) months during the course of construction.

Documents

1 file

Subscribe to get this document.

Similar open bids

In Ohio