BC-21506-B 25-129 Solar Installation – Phase 1 RFP

Active BPM059850 RFPUtilities & EnergyUniversity of Maryland, Baltimore County
The full text, documents and contacts of this bid come with a ProposalWorkspace plan.Get started

At a glance

University of Maryland, Baltimore County (Maryland) posted this RFP on Nov 20, 2026. Responses are due Jan 15, 2027. Category: Utilities & Energy. Questions are due 2026-12-18 10:00. Solicitation number BPM059850.

Solicitation details

General information

Solicitation number
BPM059850
Notice type
RFP
Place of performance
Maryland
Questions due
2026-12-18 10:00

Agency and category

Agency
University of Maryland, Baltimore County
Category
018Utilities & Energy
Source listing
Link with a plan

About this listing

ProposalWorkspace summary

This bid was found on the agency's procurement portal. The portal's own text is not republished here; the summary below was written by ProposalWorkspace's AI from the bid documents. The full posting is on the portal - subscribe to get the link.

Summary

AI-read from the bid documents

Summary fields on this page were extracted by AI from the bid documents. Always verify dates, amounts and requirements against the official solicitation.

What the bid is for

The University of Maryland, Baltimore County (UMBC), established in 1966, sits on approximately 482 acres of land. In line with the University System of Maryland (USM) and State of Maryland climate goals, the University is seeking a third party to execute a Power Purchase Agreement (PPA) to design, install, own, operate, maintain and finance solar photovoltaic systems, from which the University will purchase the power generated for a period of 25 years.

Scope

Planning and Design

With this as a reference, provide a schematic design, 50% construction documents, and 100% construction documents submission for approximately 1 MW solar construction:

  • Warehouse Rooftop
  • North Stadium Lot Carport Canopies
  • Striping
  • New parking lot lights impacted by the solar design

All vendors shall develop their own design documents and note any significant deviations from the Solar Installation Study in their proposals.

Construction

  • UMBC is its own authority having jurisdiction (AHJ). For permits beyond UMBC’s jurisdiction (e.g. MDE), obtain all permits required to complete the system, including payment of any permit fees.
  • All materials shall be reviewed by the University through a submittal review process and installed under the supervision of personnel holding current NABCEP PV Installer certificates.
  • Retain only qualified roofers to perform necessary roof penetrations, and only in conformance with the existing roof warranties.

System Startup

  • Performance test reports that verify that the PV systems achieve the performance requirements of the contract.
  • Fully executed IA and acceptance by BGE.
  • Electronic copy of as-built drawings, O&M manuals, warranties, and safety procedures specific to the system at each site.
  • 25-year roof penetration and building penetration warranty.

Operation and Maintenance

  • Maintain the system for the stated service life to at least include any cleaning, upgrades, repairs, etc. to ensure continuous delivery of electricity.
  • Provide two weeks’ notice prior to scheduling any planned maintenance and repairs and outages.

Financing

  • Deliver electricity to the University under a long-term (25 years) PPA, providing a rate schedule over the contract term. Fixed rate schedules are preferred but variable rate schedules are acceptable.
  • Arrange and execute the full financing for the life of the project.
  • Within 90 days of contract execution, provide a letter of commitment from a financial group that will underwrite the project.
  • UMBC will provide $600/kWDC up to $750,000 total as a one-time lump-sum payment at the initiation of work.

End of Service Life

The University shall reserve the right, at the end of the contract term, to one of the following:

  • Require the Vendor to decommission and remove the system from the building and parking lot.
  • Offer the System to the University at a fair market value as determined by an independent appraiser approved by both parties.

Additional information

Submission

The technical proposal shall be submitted electronically no later than the date and time indicated on the Key Information Summary Sheet. Email to: Technic.h1ykfgqqs2u688rq@u.box.com. Submit technical and financial proposals in two (2) separate files. Any attachment, or cumulative attachments, at or exceeding 150MB in size will not be accepted by the University email system. Zip files will also not be accepted by the University.

Evaluation

Technical and financial merit shall be equally important. The technical evaluation criteria are listed below in descending order of importance:

  • Offeror’s Response to RFP Objectives and Requirements
  • Past Performance and References
  • Offeror’s Capacity and Experience
  • Proposed Management and Project Personnel
  • Cost Proposal
  • Design and Construction Schedule

**Mandatory** pre-proposal conference and site visit. Minority Business Enterprise (MBE) Subcontracting Goal: 10%.

Bond and Insurance

The successful offeror shall be required to submit a performance bond for the full amount of the first year’s contract value, and renew the bond at the beginning of each contract year. Commercial General Liability Insurance including all extensions; $2,000,000 each occurrence; $2,000,000 personal injury; $2,000,000 products/completed operations; and $2,000,000 general aggregate.