Inspect and Repair of 13.2KV Main Switchgear

Active 70ZH1526QCGA00009 Combined Synopsis/SolicitationTotal Small Business Set-Aside (FAR 19.5)US Coast Guard
The full text, documents and contacts of this bid open with a free account.Sign up free to read it

At a glance

USCG Academy of US Coast Guard posted this Combined Synopsis/Solicitation on Nov 5, 2026. Responses are due Nov 12, 2026. NAICS 238210 (Electrical Contractors and Other Wiring Installation Contractors), product or service code J061 (Maint/Repair/Rebuild of Equipment - Electric Wire, and Power and Distribution Equipment). Set-aside: Total Small Business Set-Aside (FAR 19.5). Place of performance: Connecticut 06320. Solicitation number 70ZH1526QCGA00009.

Solicitation details

General information

Solicitation number
70ZH1526QCGA00009
Notice type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Place of performance
Connecticut 06320

Classification

NAICS
238210Electrical Contractors and Other Wiring Installation Contractors
Product or service
J061Maint/Repair/Rebuild of Equipment - Electric Wire, and Power and Distribution Equipment

Agency

Department
Department of Homeland Security
Sub-tier
US Coast Guard
Office
USCG Academy

Description

From SAM.gov

The U.S. Coast Guard Academy requires a qualified, licensed electrical contractor to inspect, repair as necessary, test, and restore Eaton/Cutler-Hammer MVS2 13.2 kV medium-voltage load interrupter switchgear, with primary work focused on Cabinet 5 and the associated 15 kV feeder cable serving Smith Hall. The contractor shall inspect Cabinet 5 for damage or missing/cannibalized components; remove and replace three Eaton 15CLE-250E fuses; procure and deliver three additional matching fuses for on-site spares; perform insulation-resistance testing of the feeder cable in accordance with current ANSI/NETA standards; provide certified test and field-service reports; coordinate all required outages and lockout/tagout procedures with the Government; and safely re-energize the cabinet and feeder upon successful completion of repairs and testing. All work shall comply with applicable OSHA, NFPA 70E, federal, state, and local requirements, including proper licensed personnel, arc-flash personal protective equipment, site protection, cleanup, and disposal of waste materials.

Documents

3 files

Sign up free to download these 3 files.

  • Combined Synopsis Solicitation CGC Switchgear FY27.pdf
    259 KB · Oct 30, 2026
    Download
  • SOW Inspect and Repair Main Switchgear at CGA.pdf
    1.2 MB · Oct 30, 2026
    Download
  • SwithGear QA CGA Response 5NOV26.pdf
    64 KB · Nov 5, 2026
    Download

Similar open bids

Same NAICS 238210

More from US Coast Guard

Open bids, other NAICS codes